Grassroots Community based solutions for energy conservation, watershed management, alternative and renewable energy, biomass, stormwater management, land-based wastewater disposal, LEED-AP, Green Associate, continuing education training for professionals and water reuse, and outreach to Private Well Owners in the United States.
Blog Listings
Water Research - Private Well Owner Outreach Assistance
Sunday, October 11, 2015
B.F. Environmental Builds Expertise into New Water Quality Mobile App
Friday, January 2, 2015
FREE WELL WATER TESTING Pike County Pennsylvnaia
Tuesday, December 23, 2014
New PADEP Guide Regarding Water Supply Replacement and Mine Subsidence
New PADEP Guide Regarding Water Supply Replacement and Mine Subsidence -
Under Act 54, the Pennsylvania Department of Environmental Protection (PADEP) recently published a new homeowner’s Guide titled: “Water Supply Replacement and Subsidence Damage Repair”. The Guide reviews the basics of Act 54 and water supply notification within a mining area, potential water supply and subsidence impacts, and PADEP’s role in resolving damages. A copy of the new guide can be downloaded at the following link:
http://www.bfenvironmental.com/education-wkshp.php
PA Guide to Water Supply Replacement Subsidence Damage Repair (Mining).
The document does not list the specific problems or specific water quality testing, but deals with issues related to water quality change, loss of capacity, and physical subsidence. Our primary recommendations are as follows:
1. Obtain a copy of the PA Guide to Drinking Water Quality from the Keystone Clean Water Team.
2. Permit the agent or third party contractor to inspect your well and structure. If you deny access, you may waive the assumed liability.
3. You may want to have a separate Certified Water Quality Test and a Yield Test for Your Well.
4. At a minimum - For a mining Permit - Rock or Coal - we would recommend the following parameters: pH, conductivity, total dissolved solids, chloride, sulfate, alkalinity, acidity, iron, manganese, total hardness, total coliform, turbidity, color, surfactants, nitrate+nitrite, and odor. (Additional testing may be needed based on site specific conditions and land-use- So seek the advice of an expert).
5. Maintain good records related to your well depth, pump setting, and original yield.
6. Properly report your water usage planned usage. The damages related to water quantity is a function of actual use and planned use and not an unlimited supply. For example- If you well yielded 50 gpm and you only have a single family home, a decrease in the yield of the well to 10 gpm may not be considered a specific impact (unless it required expense to modify the system, lower the pump, or add storage.
7. The guidance document may not adequately address impacts to groundsource heating and cooling systems. If these types of systems are used this information should be reported and documented.
engines for only $2.99 at ineedhits.com!
Wednesday, August 13, 2014
One Solution to Bottled Water - Without Electricity NSF Standard 58
Of major significance, is the fact that under NSF Standard 58, Steam Distillation is the only stand-alone process for removal of arsenic from water.
Conquest International is the manufacturer of the Life Saver Non-Electric Steam Water Distiller Kit. The Life Saver Water Distiller is designed for both Normal Day-to-Day Living, for use inside and outside the house, for camping, other outdoor uses, and in Emergency/Survival Situations where potable water or bottled water is not available for cooking and drinking. With the Life Saver Water Distiller Kit you can produce your own Pure Distilled Water where there is no electrical power available.
Note: You will need to provide you own heat source.
More information -
Other Water Issues
1. Make Sure to Get Your Water Tested.
2. Got a Water Question - Get this Book.
3. Need other Types of Water Treatment - Arsenic, Nitrate, Bacteria, or just a filter.
4. Private Well Owner Outreach - PA / USA
Tuesday, September 3, 2013
Tap Water linked to brain eating amoeba - Get your water tested
Tap Water linked to brain eating amoeba
"Two cases of people in Louisiana who died after contracting "brain-eating amoeba" infections from their own household water systems are prompting health officials to warn about a popular home remedy for treating sinus problems and allergies.
People who use neti pots to irrigate their nasal passages and sinuses should use only water that has been boiled, filtered or distilled, said the researchers at the Centers for Disease Control and Prevention who investigated the unrelated cases, which occurred months apart in 2011 in different parts of Louisiana.
Wednesday, October 3, 2012
Chain of Custody and Baseline Testing in Pennsylvania
The Workshop will cover:
1. Introduction into Natural Gas Development – Geology, Process, Chemicals
2. Private Wells – A brief summary of Private Well Regulations in Pennsylvania
3. Quick Summary of Common Water Treatment Systems and Problems Experienced by Private Well Owners
4. Process and Goals of Baseline Testing
- What We Learned from Dimock, Franklin Forks, and other Areas.
- What We Learned from the Citizens Groundwater Database.
- Suggested Baseline Testing Parameters
5. Chain of Custody – When does it begin? Where are the common holes in the process?
6. Reviewing the Data and Using the Data to Generate Additional Work
Instructor: Brian Oram is a Professional Geologist and Soil Scientist with B.F. Environmental Consultants. He is a licensed professional geologist, licensed Well Driller, Professional Soil Scientist, and licensed Sewage Enforcement Officer in the Commonwealth of Pennsylvania with over 20 years experience in conducting hydrogeological investigations related to water supply development, contaminant migration, wetland mitigation, and land based wastewater disposal systems.
Thursday, November 29, 2012
5-8 PM Light refreshments will be provided
Cost: $85
PDH Hours: 3
Registration Deadline: November 26, 2012
http://www.wilkes.edu/pages/1703.asp
Thursday, August 2, 2012
Microbac's Massachusetts Division Earns ISO 17025 Certified Testing
Microbac's
Massachusetts Division Earns ISO 17025 Accreditation for Biological Testing on
Food Products
The A2LA accreditation certifies the laboratory to perform the following tests on food products: Aerobic Plate Count; Total Coliform; Escherichia coli; Yeast & Mold; Listeria; Staphylococcus aureus; and Salmonella.
The ISO 17025 accreditation reinforces Microbac's commitment to maintain comprehensive quality systems and test procedures, and is a result of the full commitment, strong work ethic, and dedication of Microbac’s Massachusetts Division.
To view the scope of Microbac’s Massachusetts Division’s A2LA accreditation for Biological Testing, click here.
Nancy Burnett, Division Manager
nancy.burnett@microbac.com
508-595-0010
Will Traver, Account Representative
will.traver@microbac.com
Microbac Laboratories, Inc.
100 Barber Ave.
Worcester, MA 01606
www.microbac.com
Note - If you are looking for informational water testing or certified baseline testing contact us.
Monday, May 28, 2012
Water Well Testing Harveys Lake Pennsylvania and Q&A Session Offered
Water Well Tests and Q&A Session Offered
A comprehensive package of drinking water tests will be offered once again this summer at a deeply discounted price to Harveys Lake residents ( Haveys Lake, Luzerne Wyoming County, PA) by the Water Research Center and National Testing Laboratories, Ltd. together with the Harveys Lake EAC.
The tests will be conducted on Saturday morning, July 21. On Saturday morning, August 4, a free follow-up Q&A session on water well systems and non-point source pollution issues will be held. The Q&A session is open to all residents, not just those testing their wells.
The cost of this year’s water well test package will rise to $95 (compared to a retail value of more than $225). Residents' water will be tested for Alkalinity (Total as CaCO3), Chloride, Fluoride, Hardness, Nitrate as N, Orthophosphate, pH (Standard Units), Sulfate, Total Dissolved Solids, Turbidity (Turbidity Units), Total Coliform with e. coli check, Aluminum, Arsenic, Barium, Cadmium, Calcium, Chromium, Copper, Iron, Lead, Magnesium, Manganese, Mercury, Nickel, Potassium, Selenium, Silica, Silver, Sodium and Zinc. This includes some key Marcellus Shale Indicators.
Interested residents should register with Denise, at 570-639-1042. Participants can pick up water sampling kits at the Harveys Lake Borough Building between July 9 and 21. Water samples must be dropped off between 10am and noon on July 21 at the Borough Building’s meeting room, where scientists will perform certain tests immediately. Confidential final test results will be mailed to participants directly from the Water Research Center within two weeks of the testing date. Payment in full for the testing is due on July 21.
The well water and non-point source pollution Q&A session will be conducted at 10AM on August 4 by Brian Oram, a professional geologist and water well expert who has run the testing programs here at Harveys Lake for many years. Brian will make an informative presentation and then take questions from the public. Brian’s past Q&A sessions here at the lake have been greatly appreciated by all attendees- They are fact based and provide action items to correct and evaluate problems.
Important Note: This program’s test results do not meet the requirements of a legal baseline water well test. However, these tests remain a valuable and cost-effective opportunity for homeowners to monitor the safety of their drinking water. If legal baseline testing is needed or would like to schedule a community information meeting with Q/A, please contact Mr. Brian Oram, PG at 570-335-1947 or go to http://www.bfenvironmental.com/natural-gas-exploration.php.
The Citizen Groundwater Surfacewater Database
Help to Track Change in Pennsylvania ((FREE -(NEW Web-Portal)
Private Well Owner - Watershed Survey
Possible Free Radon in Water Testing (FREE -(NEW Web-Portal)
Saturday, March 17, 2012
EPA Press Release and Statement to The Press Dimock Pennsylvania
On Jan. 19, as a result of requests from residents and a review of the data we had in hand, EPA announced it would perform water sampling at approximately 60 homes in the Carter Road/Meshoppen Creek Road area of Dimock, Pa. to further assess whether any residents are being exposed to hazardous substances that cause health concerns.
The first round of sampling results is now available for the first 11 homes that were tested during the week of Jan. 23. Sampling results from these 11 homes did not show levels of contamination that could present a health concern. Samples from six of the 11 homes did show concentrations of sodium, methane, chromium or bacteria, but concentrations were all within the safe range for drinking water. The sampling results also identified the presence of arsenic at two homes.
Out of the 11 homes tested, there are currently three homes receiving an alternate water supply provided by EPA. EPA will continue to provide water to these homes while we perform additional sampling to ensure that the drinking water quality at these homes remains consistent and acceptable for use over time. EPA is also taking a second round of samples from the two homes where arsenic was detected, and although the levels meet drinking water standards, we will resample to better characterize the water quality of these wells. After receiving results from the second round of sampling, EPA will re‐evaluate the need to continue providing an alternate water source.
EPA has offered to meet with all the residents to go over their data and answer any health‐related concerns. As further quality assured data becomes available for the remaining homes, we will share with the homeowners in an expedited manner. Our actions will continue to be based on the science and the law as we work to help get a clear picture of water quality for these homes in Dimock.
EPA Webportal for Dimock
A Well by Well - Review of the Data for Dimock, PA collected by EPA
Monday, July 4, 2011
The Best Way to Make Ice
First of all, you can make ice cubes from water produced by RO Systems. In fact, ice made from reverse osmosis, or RO, water produces cleaner, clearer and better tasting ice cubes because most of the bacterias are removed from the water. So, just because water is purified by a certain procedure, (in this case, reverse osmosis), has no bearing on whether we can make ice. I prefer “clean ice” – in many cases it is perfectly see through, except for a little bubble in the center of the ice cube. Also the benefit is that the cube is more frozen and melts less rapidly. Almost all people enjoy that as well.
So, why would an ice maker technician tell someone that RO water will not function on an ice machine? I can’t help but to suspect that through his experience, he has witnessed many situations where he is summoned on a service job and noticed that when the RO Treatment Systems was turned off and the ice-maker was connected directly to the natural supply, it functioned. This however does not mean that a Reverse Osmosis Treatment Systems will not make ice cubes. When one supplies a considerable volume of water at an adequate pressure, any ice-maker will produce wonderful ice-cubes through reverse osmosis.
The challenge with a RO Systems on ice-makers, especially the bar style ice-makers, is that those types of ice machines use a tremendous supply of water. Believe it or not, some of those makers can use 80-90 gallons of water a day! Unless you have a high volume RO Systems, it is futile to try and generate Reverse osmosis water to that genre of ice-maker.
Another challenge is pressure. Many newer model ice machines need 30-40 PSI (pounds per square inch) to function properly. A home RO Systems drops the incoming pressure by 30-35% if you are starting out with 70-80 pounds per square inch, that is ok, but if the incoming water pressure is 40-60 pounds per square inch, there may be an obstacle. Volume and pressure are separate obstacles. You may have adequate pressure to operate an ice machine, but not sufficient volume and it’s not as simple as installing another tank with enough of volume and minuet pressure.
measuring a RO Treatment Systems is substantial when you have a few water outlets, especially if some of them are an under-the-counter ice-maker. Most in home reverse osmosis systems are 24 to 50 gallons per day, or GPD, which is not nearly adequate enough for such an ice-maker. Also, creation is decreased whenever the water temperature is less than 77 degrees F, and whenever the pressure is below 60 Pounds per square inch. In our world, a 50 GPD RO Treatment Systems in the Midwest will likely produce 20-25 GPD, when the demand can be up to 150 GPD.
There are many simple answers, and the awesome news is that they do not have to be considerably costly. One strategy is to install a bigger system, such as a 300 gallons per day reverse osmosis systems or a high production system, such as GE’s Merlin system, which produces 1/2 GPM of Reverse Osmosis water. Another idea is to super charge the pressure coming in with a booster pump or turbo charging the reverse osmosis system pressure to 80 pounds per Square Inch with a Demand Delivery Pump. This type of system will supply plenty of excellent, great-tasting RO Systems water, without ever running out! So, you can use RO Systems water on ice makers, and businesses, such as ours can even install RO Treatment Systems on very large non-residential machines. If we are able to do that, your residential ice machine will be simple} to [clean up and supercharge to Reverse Osmosis Treatment Systems ice. The key is properly sizing the RO Treatment Systems and pressure needed to glorify output. Look for a company that will do just that, and relax with a cold beverage and fresh ice.
For More Information about Reverse Osmosis and Water Softeners
other water treatment systems and informational water testing services
Friday, August 13, 2010
MAGNESIUM IN DRINKING WATER
The UN’s World Health Organization (WHO) has just recommended that drinking water contain 25-50 mg of magnesium per liter to prevent deaths from heart attack and stroke: www.MgWater.com/download American bottled water averages <5 mg of magnesium (Mg) per liter, while bottled water in the rest of the world averages about 20 mg of magnesium per liter. The US National Academy of Sciences estimated that the US deaths from soft water were 150,000 per annum, and that was in 1977!
The FDA and the US Department of Justice (DOJ) caused the Mg-deficient-water problem by Un-Constitutionally destroying the American mineral water industry in the 1930’s, in the mistaken belief that pure water was good, and that mineral water was just impure water. No other country has ever destroyed their mineral water industry.
For decades, the evidence has been overwhelming that Americans are very deficient in Mg, as evidenced by the 23% shortfall from the RDI, yet the FDA and DOJ have covered up their blunder, getting a Federal lawsuit dismissed before the evidence could be shown, and keeping silent about the millions of deaths indicated by over 50 epidemiological studies from nine countries. Recent studies clearly confirm that water-borne Mg is far, far better in preventing cardiovascular pathologies than food-borne Mg.
Epidemiological studies indicate that millions of Americans have died due to the FDA’s and DOJ’s destruction of the American mineral water industry. See:
www.mgwater.com/anderson.shtml
www.mgwater.com/finland.shtml
www.mgwater.com/lancet.shtml
www.mgwater.com/singh.shtml
Now, it is up to the FDA and DOJ to end this travesty, requiring the Mg content of bottled or canned beverages to be put in labels’ nutrition panels, and requiring that all bottled or canned beverages contain at least 25 mg of Mg per liter. FDA and DOJ have ignored petitions and a lawsuit, continuing to cause vast numbers of deaths just to cover-up their blunder.
It is not practical to fortify tap water with magnesium, because 99% of tap water is used for washing, flushing, etc., not drinking, so the cost of fortifying tap water would be prohibitive.
The best way of Mg-fortifying beverages is with "magnesium bicarbonate", as the bicarbonate has the added benefit of reversing the harmful acidification found in aging bodies. Magnesium bicarbonate is made by adding magnesium carbonate to carbonated water, which reacts.
Paul Mason, Mg Librarian
http://www.mgwater.com/
Adobe Springs Water Co. LLC
paulmason@MgWater.com
Note: I tend to agree that softened water is not the best and water with very high hardness, i.e., very hard water, can create aesthetic problems (staining, coatings, films, difficulty washing using soaps, etc)- This article is not an endorsement of the product or company.
More inforamtion on water quality - Free Booklet at
http://www.wilkes.edu/water
Saturday, March 27, 2010
PA HB 1205 - Proposed changes Oil and Gas Law
Based on a review of this house bill - I like the following items:
1. Increasing the baseline radius to 2000 feet - but this does not address the issue of the horizontal leg of the well and does not really address local geology. It is important to note that it is my professional opinion that the fracing process or horizontal leg of the well is not the point or portion of the drilling that is a primary area of concern. The primary area of concern is the area around the well and drilling pad and the vertical wellbore construction and prevent of surface leaks and spills. A company needs to have a Spill Prevention and Action Plan.
2. Increasing the time line - I am not sure 2-years is the best number, but it is better than 6 months.
3. The issue of prior contamination and timing in the law- the wording could be interpreted to mean that the baseline quality is solely based on an analysis that was collected 30 days prior to drilling. This is not appropriate - If this raises a question in my mind - this is a potential weakness in the wording of the law.
4. The notification time line is not appropriate -the private well owners should be notified within 48 hours if there is a problem with the water quality that may pose a health concern and receive a written report in 30 to 60 days - 10 days for written is creating paper work - they need to get a copy of the testing results and there should be some form of education to help them understand the results and take action if needed.
5. Follow up water testing as written is not appropriate - if the time line is two years. Then the gas company should test the water at least once a year for two years. The follow-up testing should include the parameters tested in the initial baseline, plus any parameters specific to the chemicals or processes used in developing the well (see comment 8).
6. The proposed law does not address the issue of a possible contaminant event or concern. The owner should have the right to have the Commonwealth Investigate water quality contamination events and the cost reimbursed by the Gas Company or a fund established by the Gas Company- if a gas company is found responsible. If some other agent is found responsible - the PADEP should act on behalf of the private citizen to correct this issue.
7. A fund should be established to help improve, fix, or abandon wells (Cement or grout them closed) that are identified as contaminated during the initial baseline assessment or found to be vulnerable pathways for future contamination. It is in the benefit of the Commonwealth to eliminate this route of contamination or potential impact to the community.
8. Frac chemicals - I believe the listing of chemicals and MSDS sheets a company may used in the process is listed in the permit application to the state. At a minimum, the Spill Prevention Plan should require the company to have MSDS sheets for these chemicals on-site, spill containment systems for these chemicals, and provide a summary of the chemicals and quantities used in the frac process or other processes.
Just my thoughts
Brian
Tuesday, February 2, 2010
Getting Your Water Tested – Why?
The sampling process used for regulated water supplies follows a protocol known as a Chain-of-Custody. For this process, a third-party person, i.e., not the wellowner or an interested party, that has been trained and approved by a certified laboratory will collect a water sampling following approved and standard practices. This individual will document the time and location of the testing, specific the list of parameters to be tested, document the water conditions in the field, and in some cases conduct some type of field testing or analysis. The third party sampler should document the type of water source, i.e., well, spring, or surfacewater. If the water is treated, the third party sampler should document the type of treatment system. If the private well has a treatment system, it may be advisable to collect a water sample before and after the existing treatment system. The sampler then properly labels the containers, completes the chain-of-custody documents, and transports the samples as required by the state-certified or National Environmental Laboratory Accreditation Program (NELAP) certified laboratory. The sampler role is to make sure the samples were properly collected, preserved, and transported to the laboratory. When the sampler returns to the laboratory, the certified laboratory will review the sampling and collection process, check sample temperature, and review chain-of-custody sheet. If the sampler followed the laboratory protocols, the laboratory will accept the samples and sign the chain-of-custody documents. These documents will follow the sample through the laboratory testing process and a copy of this sheet will typically be provided with the laboratory results. The certified laboratory is required to maintain a copy of these records for a period of at least five years. Because the records are owned by the client, it is strongly recommend that the private well owner or water supply owner contract with the laboratory rather than relying on a company or corporation to pay to conduct this background analysis. If you rely on a company or corporation to pay or contact with the laboratory, it would be in your best interest to have the company agree to provide you a copy of the results within a timely manner and you should be given the right to directly request copies of the results from the laboratory. By using this process, the data that is collected should withstand cross-examination and be supportive of any legal action.
There is no statewide certification for water samplers, but it would be advisable to use an individual that is approved by the laboratory, an individual that carries a profession license, or by an agent for the laboratory. Because the sampling and laboratory testing may be part of a legal action, it would be advisable to use an individual that is a licensed professional or an employee of a certified laboratory. It would be best if this individual is experienced and has provided expert testimony in the Commonwealth. If you would like more information on drinking water quality in Pennsylvania, I would recommend you visit the Center for Environmental Quality at Wilkes University – http://www.water-research.net. Regarding baseline sampling, it is best if this testing is conducted prior to major construction or exploration activity, but even after activity may have started this information will provide a baseline for documenting the existing conditions of the water supply. In addition to documenting water quality and appearance, it may be advisable to document the static and dynamic water level in the well and yield of the well.
If you are interested in participating in the development of a regional database of water quality data for private wells, please contact Mr Brian Oram at Wilkes University- brian.oram@wilkes.edu. If you would like more information on background water quality analysis and laboratory testing or would like someone to meet with you or your group, please contact B.F. Environmental Consultants at http://www.bfenvironmental.com or (570) 675-0253.
Respectfully submitted
Mr. Brian Oram, PG
Saturday, September 19, 2009
B.F. Environmental Inc. Partners with National Water Testing Business
The featured water testing package is the Well Check Water Testing package. This package our well water testing package that includes microbiological testing (Total Coliform & E-Coli) and the analysis of 19 heavy metals & minerals, 6 inorganic chemicals and physical factors. This package helps homeowners to determine what is in their well water and if a treatment system is needed. This package is a great follow up test for our customers who are using our Watercheck test package and need to determine if new treatment systems are working to correct any bacteria or metals issues that were detected. This product also benefits anyone who is looking to monitor their well water on a regular basis. There is no more reliable, easier, faster, or cost effective way for testing your drinking water". For more details follow this Informational Water Testing Program .
For additional outreach services and information on water treatment, visit us at
Carbon-Filtration.com
Looking for more Free Information - Visit our Online Helpguide - Its Free !
Tuesday, May 5, 2009
Private Well Construction Standards for Pennsylvania
Private Well Construction Standards
Why?
1. Protect health and safety for the citizens.
2. Ensure the long-term quality, quantity, and reliability of the groundwater aquifer.
3. Prevent direct and indirect contamination of the aquifer.
4. Minimize the adverse impacts to the environment.
5. Private wells are currently not regulated under Pennsylvania Code, Chapter 109.
6. Pennsylvania is second among all states in the number of residences served by private water wells, with more than a million households relying on private wells. But Pennsylvania is among just two states that do not have private water well construction standards or certification requirements for drilling contractors and operators.
7. Improperly constructed private wells facilitate groundwater contamination.
What is a private well?
This is a well that does not meet the definition of a public water system. A private well is a well that has less than 15 service connection or serves less than 25 people daily for at least 60 days per year (PADEP, Non-Community System Design Standards, Document No 383-2128-108 (5/21/2001)).
Current State Law (Pennsylvania)
1. Public water systems (PADEP) or withdrawals of over 20,000 gpd are regulated (River Basin Commission). This regulations related to the siting, construction, testing, operation, water withdrawal, regular reporting, and consumptive use.
2. Proposed regulations may require systems of 10,000 gpd or more to be registered and reported to the PADEP (Water Planning Act 220, December 2002) Act 220 does NOT include metering of home water wells.
3. Act 610 requires a licensed driller to drill any well for the purpose of accessing groundwater. This includes, in addition to wells for water withdrawal, wells for geothermal heat systems, monitoring or observation wells, test wells, recharge wells, and waste disposal wells. Although Act 610 has required drillers to submit records for all wells drilled since 1966, at times they are less than diligent at doing so. Because there is no registration of individual wells we have no way of verifying how many wells each driller completes in a year. (Water Well Drillers License Act, the act of May 29, 1956 (P.L.1840, No.610), 32 P.S. Sections 645.1-645.13 ). The act has a provision for well abandonment, but there is no tracking or registration for individual private wells.
http://www.dcnr.state.pa.us/topogeo/groundwater/Act610.aspx
Key Features of a Well Ordinance - My Suggestions
1. Standards should relate to private – non-regulated wells.
2. Provide Isolation Distances that include recommendations for set-backs from building foundations, floodways, animal feedlots, septage disposal areas, chemical storage areas, etc. and not just isolation distances from septic tanks, property lines, and disposal fields.
3. Standard should provide the recommendation for the use of steel casingThe casing should be 19# casing that is either threaded and coupled or welded around the perimeter by a certified welder and the casing should be fitted with a driveshoe.
4. Casing should penetrate – a minimum of 40 feet below grade and 10 feet into firm bedrock, whichever is greater.
5. All wells should be fitted with a sanitary seal and all wells should have the annular space cement or neat cement grouted. The grout should extend to the anticipated depth of the pitless adapter. The casing should extend at least 18 inches above grade and outside of the floodplain or floodway. If within the floodplain, the casing should extend 3 feet above the 100 year flood elevation.
6. All wells should be shock disinfected and purged.
7. All wells should have a well drilling log and yield test. Yield test should be a minimum of a blown yield test.
8. Wells should be sampled and tested. At a minimum, the testing should be for pH, conductivity, total coliform, iron, mangansese, total hardness, and alkalinity.
9. Ordinance should require that the driller submit information to the local agency, landowner or homeowner, and other agencies as required by law.
10. Require well drillers to complete a more formal training and certification process, such as the program developed by the National Groundwater Association.
11. Develop and encourage the creation of community educational programs, such as the Carbon County Groundwater Guardians - http://www.carbonwaters.org/
and the Center for Environmental Quality at Wilkes University - Homeowner Outreach Program
http://www.water-research.net/
Article Prepared by Mr. Brian Oram, Professional Geologist
B.F. Environmental Consultants Inc.
http://www.bfenvironmental.com/
Saturday, May 2, 2009
Marcellus Shale - Citizens and Royality Owners Northeastern Pennsylvania Background Water Testing
B.F. Environmental Consultants Inc. provides environmental consulting and education outreach services to landowners and other organizations. The primary focus of our natural gas outreach efforts is to aid in evaluating and documenting baseline environmental conditions and to educate citizens on the natural gas development. These services include assisting in documenting baseline environmental conditions and helping landowners to understand the baseline environmental quality. The primary purpose of this website is to help educate and inform the public, landowners, municipal officials, and other organizations.
B.F. Environmental Consultants Inc. has prepared a summary or a series of background water testing packages to help local citizens, community groups, and royality owners document baseline water quality. In order to maintain chain-of-custody, a professional geologist or other trained professional will collect the water sample, document existing conditions, and if necessary document the static water level in a well or flow in a stream or spring. The samples will be field tested and screened and then submitted to a certified testing laboratory for analysis. The testing packages have been developed based on a review of the available recommendations by Penn State University, Wilkes University, PADEP, other research facilites, and a review of the background quality of the water in the Marcellus Shale and data from frac water collected from a Northeast Pennsylvania Drilling Site.
To obtain more information, please visit:
http://www.bfenvironmental.com/natural-gas-exploration.php