Showing posts with label Dimock PA. Show all posts
Showing posts with label Dimock PA. Show all posts

Sunday, June 17, 2012

Private Well Water Quality Susquehanna County Dimock PA



Comment

1. Without predrilling data, it is not possible to comment on the cause for any water quality problems.
2. Where possible, I have noted situations where elevated levels of a water quality parameter exists in Pennsylvania.
3. If duplicate analysis provided, I attempted to use the highest reported value.
5. This is not about cause and effect; it is about a review of the data.

Well – HW-20 (1/30/2012)

With the exception of the following parameters, the remaining values were reported as NOT Detected (U)

Heterotrophic Bacteria – 67 colonies per 100 ml ( I do not understand the J value).  The drinking water limit is < 500 colonies per 100 ml (OK).

Total Coliform < 1 colony per 100 ml (OK)

Aluminum – < 0.030 mg/L (Total) - drinking water standard ranges from 0.05 to 0.2 mg/L.   This parameter is regulated as a secondary drinking water standard, because of aesthetic reasons.   The treated water level of aluminum is < 0.030 mg/L.  (OK)

Anionic Surfactants –< 0.01 mg/L – the secondary drinking water standard for foaming agents is 0.5 mg/L.  (OK)

Arsenic – < 0.002 mg/L – drinking water standard is <  0.010 mg/L – this does not suggest any specific impact and arsenic is a common problem in NEPA – about 6 % of private wells have arsenic above 0.010 mg/L.  The treated water level of arsenic was
< 0.002 mg/L and treated and filtered < 0.002 mg/L.  (OK)

Barium – 0.0328 mg/L – the primary drinking water standard for barium is 2.0 mg/L –– this does not suggest any specific impact and barium is typically detectable in non-saline impacted water at a level of less than 1 mg/L. After treatment, the concentration is 0.0329 mg/L.  (OK)

Bromide – < 0.5 mg/L - In freshwater, bromide is typically less than 0.05 mg/L. Therefore, it would be advisable to retest using a method with a lower detection limit.

Other References

Boron –< 0.050 mg/L (Total) – no specific drinking water standard drinking water standard is available. EPA appears to have a long-term health advisory of 2.0 mg/L, but other states have limits that range from 0.6 to 1 mg/L.  

Calcium- 22.40 mg/L (Total)– no specific drinking water standard drinking water standard is available.  After treatment, the level of Calcium is 22.10 mg/L.(OK)

Chloride –3.41 mg/L (OK) – drinking water standard is <  250 mg/L – this does not suggest any specific impact.   After treatment, the reported value was 3.1 mg/L (OK).

Chromium-< 0.002 mg/L (D) and the EPA/ PADEP primary drinking water standard is
< 0.100 mg/L (OK).

Copper – 0.0045 mg/L  (Untreated) - the secondary drinking water standard is 1.0 mg/L and the primary drinking water standard is 1.3 mg/L. (OK)  At the tap the level was 0.0039 mg/L.

Ethane –< 0.0012 mg/L  – No specific drinking water standard (OK)

Fluoride – 0.109 mg/L – drinking water standard is < 2 mg/L- PADEP drinking water standard is 2 mg/L.   After treatment, the reported value was 0.124 mg/L (OK).

Iron – < 0.100 mg/L (Total) – Iron is regulated as a secondary drinking water standard in Pennsylvania and the action limit is 0.3 mg/L.  Therefore, the total iron content does not exceed the secondary drinking water standard.  (OK)

Lead – 0.0024 mg/L (Total) - Lead is regulated as a primary standard (EPA and PA) at 0.015 mg/L, but the action level in PA for source water is 0.005 mg/L. (OK)

Lithium – < 0.200 mg/L (Total) – no specific drinking water standard drinking water standard is available, but EPA has recommend a level be below 0.7 mg/L    (OK)

Methane   < 0.0095 mg/L   – No specific drinking water standard.  The well water is below the new action limit of 7 mg/L.   After treatment, the level of methane is < 0.0095 mg/L. For more details, go to http://www.water-research.net/methanegas.htm

Magnesium-5.71 mg/L– no specific drinking water standard drinking water standard is available.  (OK)  The treated water level of magnesium was 5.57 mg/L.

Manganese– 0.0026 mg/L (Total) – Manganese is regulated as a secondary drinking water standard in Pennsylvania and the action limit is 0.05 mg/L.  Therefore, the total manganese content does not exceed the secondary drinking water standard.   After treatment the level is 0.0023 mg/L. (OK)

Nickel – < 0.001 mg/L  – no specific drinking water standard drinking water standard
is available, but the EPA has suggest a MCL of 0.1 mg/L.   (OK) 

Potassium – <  2.0 mg/L (Total–  no specific drinking water standard drinking water standard is available (OK)

Sodium –6.21  mg/L  – no specific drinking water standard drinking water standard is available, but the EPA has added it to the Candidate List to provide more analysis.  The EPA’s initial value of 20 mg/L has been clearly identified as not realistic.  When chloride (salt is sodium chloride) is present at a concentration of over 250 mg/L, the water can have an “off” taste. At 400+ mg/L chloride, the water will taste definitely salty. (Source- Dr. Brian Redmond, Professional Geologist).  After treatment, the level was 6.04 mg/L. (OK)

Sulfate –5.73 mg/L (OK) – drinking water standard is <  250 mg/L – this does not suggest any specific impact.

Strontium < 0.200 mg/L   – no specific drinking water standard drinking water standard is available, but it is on the EPA Candidate List.  The EPA recommends that drinking water levels of nonradioactive strontium should not be more than 4 mg/L.  The report limit is consistent with background levels in Northeastern Pennsylvania.  If the background level was above 4 mg/L, it would be advisable to test for radiological parameters, especially alpha/beta.  (OK)  After treatment, the level is < 0.200 mg/L.

Total Dissolved Solids  48 mg/L  (Value appears low) – Total Dissolved Solids is regulated as a secondary drinking water standard by the PADEP in Pennsylvania and the action limit is 500 mg/L.  After treatment, the level was 109 mg/L (OK- Retesting Recommended).

Total Suspended Solids - < 10 mg/L – no standard, but would recommend retesting to obtain a lower detection limit.

Uranium –< 0.001 mg/L (Total) – Uranium is regulated as a primary drinking water standard by the EPA and PADEP in Pennsylvania and the action limit is 0.030 mg/L.  (OK)

Zinc  0.0127 mg/L – Zinc is regulated as a secondary drinking water standard by the PADEP in Pennsylvania and the action limit is 5.0 mg/L. After treatment, the level of zinc was 0.0158 mg/L. (OK)

Nitrate+Nitrite- N – 0.42 mg/L, this is well below the EPA / PADEP drinking water limit of 10mg N/L for nitrate-N and would also be below the limit of 1.0 mg N/L for nitrite-N. (OK)

Acetone - the reported value was < 0.002 mg/L.  PADEP has a Medium Specific Concentration (MSC) for aquifers with a TDS of < 2500 mg/L of 33.0 mg/L and Massachusetts appears to have a drinking water standard of 6.3 mg/L. (OK)

Bromoform – < 0.0005 mg/L – the Total Trihalomethane Group has a limit of 0.08 mg/L, but bromoform should be less than 0.004 mg/L.  (OK)

Methyl ethyl ketone – < 0.002 mg/L in the treated water and untreated water. (OK)
Methyl ethyl ketone is a colorless volatile liquid that is soluble in water. The odor threshold for methyl ethyl ketone is 5.4 parts per million (ppm), with an acetone-like odor reported. Methyl ethyl ketone is also referred to as 2-butanone.   The EPA and PADEP has not set a drinking water standard, but it appears that Massachusetts has set a level of 4 mg/L.
http://www.epa.gov/ttn/atw/hlthef/methylet.html

Ethylene glycol –  the reported value is < 10 mg/L – there is not standard, but the EPA has a guidance limit of < 7 mg/L.  Other states have lower and higher standards:

New Jersey 0.300 mg/L (300 ppb)
Arizona 5.5 mg/L (5500 ppb)
New Hampshire 7.0 mg/L (7000 ppb)
Florida, Massachusetts, and Minnesota14.0 mg/L (14,000 ppb)
Minnesota

At a minimum, I would recommend retesting for ethylene glycol other and glycol-type compounds using a method that is more sensitive or conducting some type of standard additions analysis.  In addition, it would be advisable to retest the level of total dissolved solids and conduct a first flush test for copper, lead, and zinc.

This document can not be copied in whole or part without the expressed written permission of Mr. Brian Oram, B.F. Environmental Consultants Inc. http://www.bfenvironmental.com

Do you want to make a positive change in PA - that will cost you NO Money?
Help Support the Citizens Groundwater and Surfacewater Database and Submit Your Baseline Data !

 Free Information on Drinking Water Quality - http://www.water-research.net







Monday, April 2, 2012

HW-19 EPA Water Test Dimock PA Pennsylvania Natural Gas Migration


Comment

1. Without predrilling data, it is not possible to comment on the cause for any water quality problems.
2. Where possible, I have noted situations where elevated levels of a water quality parameter exists in Pennsylvania.
3. If duplicate analysis provided, I attempted to use the highest reported value.
5. This is not about cause and effect; it is about a review of the data.


Well – HW-19

With the exception of the following parameters, the remaining values were reported as NOT Detected (U)

Anionic Surfactants – 0.01 mg/L – the secondary drinking water standard for foaming agents is 0.5 mg/L.  (OK)

Heterotrophic Bacteria – 24 colonies per ml – the general guidance for “standard plate count” or total bacterial count is < 500 colonies per ml (OK)

Ethane < 0.0012  mg/L  – No specific drinking water standard (OK)

Methane < 0.002 mg/L  – No specific drinking water standard. (OK).

Ethylene glycol –  the reported value is < 10 mg/L – there is no standard, but the EPA has a guidance limit of < 7 mg/L.  Other states have lower and higher standards:

New Jersey 0.300 mg/L (300 ppb)
Arizona 5.5 mg/L (5500 ppb)
New Hampshire 7.0 mg/L (7000 ppb)
Florida, Massachusetts, and Minnesota14.0 mg/L (14,000 ppb)
Minnesota

At a minimum, I would recommend retesting for ethylene glycol other other glycol compounds using a method that is more sensitive or conducting some type of standard additions analysis.

Chloride – 19.10 mg/L (OK) – drinking water standard is <  250 mg/L – this does not suggest any specific impact.

Sulfate – 18.20 mg/L (OK) – drinking water standard is <  250 mg/L – this does not suggest any specific impact.

Arsenic – < 0.001mg/L (Total) and 0.002 mg/L (D) – drinking water standard is <  0.010 mg/L – this does not suggest any specific impact and arsenic is a common problem in NEPA – about 6 % of private wells have arsenic above 0.010 mg/L.  

Barium - 0.229 mg/L (Total) and 0.234 mg/L (D) – drinking water standard is <  2 mg/L – this does not suggest any specific impact and barium is typically detectable in non-saline impacted water at a level of less than 1 mg/L. (OK)

Calcium- 37.6 mg/L (Total) and 41.6 mg/L (D) – no specific drinking water standard drinking water standard is available.  (OK- but there is either a contaminant added during filtration or this represents lab error – Higher Filtered Sample Higher than Total)

Chromium- 0.002 mg/L (Total) and 0.0032 mg/L (D) and the EPA/ PADEP primary drinking water standard is < 0.100 mg/L (OK).

Copper – 0.0074 mg/L (Total) and < 0.069 mg/L (D)- Copper is regulated as a primary standard (EPA and PA) and secondary drinking water standard in Pennsylvania.  Primary standard 1.3 mg/L and secondary standard 1.0 mg/L.   (OK)

Magnesium- 7.12 mg/L (Total) and 7.72 mg/L (D) – no specific drinking water standard drinking water standard is available.  (OK)

Manganese– 0.0082 mg/L (Total) and < 0.001 mg/L (D) – Manganese is regulated as a secondary drinking water standard in Pennsylvania and the action limit is 0.05 mg/L.  (OK)

Nickel - 0.0016 mg/L (Total) and 0.0017 mg/L (D) – – no specific drinking water standard drinking water standard is available, but the EPA has suggest a MCL of 0.1 mg/L.   (OK)

Sodium –9.03 mg/L (Total) and 10. mg/L (D) – – no specific drinking water standard drinking water standard is available, but the EPA has added it to the Candidate List to provide more analysis.  The EPA’s initial value of 20 mg/L has been clearly identified as not realistic.  When chloride (salt is sodium chloride) is present at a concentration of over 250 mg/L, the water can have an “off” taste. At 400+ mg/L chloride, the water will taste definitely salty. (Source- Dr. Brian Redmond, Professional Geologist). (OK)


Zinc  0.0069  mg/L (Total) and 0.0053 mg/L (D)  – Zinc is regulated as a secondary drinking water standard by the PADEP in Pennsylvania and the action limit is 5.0 mg/L.  (OK)

Total Dissolved Solids  148 to 173  mg/L   – Total Dissolved Solids is regulated as a secondary drinking water standard by the PADEP in Pennsylvania and the action limit is 500 mg/L.  (OK)  This is a significant range in TDS – it may be worth checking to see if the “P” sample was field contaminated or if there was an increase in the conductivity during the purging process. (OK)

Nitrate+Nitrite – 2.38 mg N/L, the EPA drinking water for nitrate-N/L is 10, but the primary drinking water standard for nitrate is 1 nitrite-N/L.  It is probably be ok, but it may be advisable to test for nitrite-N.  (OK)

No major problems

1. Heterotrophic bacteria present- but that is common in NEPA. 
2. Nitrate-Nitrite at 2.38 mg/L – it may be advisable to check the level of nitrite in the water.
3. Retesting for glycols using a more sensitive technique is recommended.
4. Water did not contain methane gas, it was not detected.



Document can not be copied in whole or part without the expressed written permission of Mr. Brian Oram, B.F. Environmental Consultants Inc. http://www.bfenvironmental.com

Do you want to make a positive change in PA - that will cost you NO Money?
Help Support the Citizens Groundwater and Surfacewater Database and Submit Your Baseline Data !

 Free Information on Drinking Water Quality - http://www.water-research.net